Main Image
Main Image
Talk to our Engineers

Need Real Answers for your Specific Use Case? Talk to our Engineers

No sales scripts. Just technical feasibility:

Call us at 1-866-400-1300

or

E-mail

Tension/Compression Load Cell

Kyowa Americas Inc

Generating/Updating Your Configure-to-Order tool...

See product documents

1

The W5 Engineering Advantage

Icon for award

20+ Years in Testing

Icon for users

All Across North America

Icon for trust

Trusted by Industry Leaders

Icon for clock

24-Hour Engineering Replies

Icon for users

Secure Order Processing

Icon for Award

ISO-Level Quality Assurance

Overview
Specifications
Resources

What it is

LUK-A is a thin load cell for measuring tension or compression loads. It can be installed where the height is limited. It is also suitable for fatigue tests where repetitive loads are applied continuously.

The Kyowa LUK-A is a thin, strain gage tension/compression load cell rated from ±1,124 lbf to ±449,618 lbf (±5 kN to ±2 MN). Its low profile suits installations with height restrictions and fatigue tests where a continuous load is applied. Nonlinearity and hysteresis are within ±0.1% RO up to 200 kN, and the housing is rated IP64.

  • Rated capacity: ±1,124 … ±449,618 lbf (±5 kN … ±2 MN), nine models
  • Tension and compression: rated output +2 mV/V ±1% in tension (5 to 20 kN: 2.4 mV/V ±10%)
  • Accuracy: nonlinearity and hysteresis within ±0.1% RO (500 kN and larger: within ±0.2% RO)
  • Low temperature effects: within ±0.005% RO/°C on zero and ±0.005%/°C on output
  • Natural frequency: 3.9 … 11 kHz (approx.)
  • Protection: IP64 (JIS C 0920/IEC 60529)
  • TEDS-installed models available
  • Conforming to CE and RoHS

What it is used for

Some of the use cases for the LUK-A include:

  • Installations with height restrictions — thin tension/compression measurement
  • Fatigue tests — where a continuous load is applied
  • Hanging load measurement — with the shaft prevented from turning

Features

Compact & lightweight

The service life can be extended by using under one-half of the rated capacity.

TEDS-installed versions can be manufactured.

What does the LUK-A measure?

The LUK-A measures tension and compression force applied to its center, with the outer peripheral surface fixed. Strain gages form a 350 Ω bridge, producing an output proportional to the excitation voltage. Sensitivity difference between loading directions is 0.4% RO or less.

Why engineers pick it

  • Thin for its capacity. The LUK-A family covers ±5 kN to ±2 MN in a low-profile shape suited to installations with height restrictions.
  • Accurate in both directions. Nonlinearity and hysteresis are within ±0.1% RO, repeatability 0.05% RO or less (500 kN and larger: ±0.2% RO and 0.1% RO), and the sensitivity difference between loading directions is 0.4% RO or less.
  • Stable over temperature. Temperature effect is within ±0.005% RO/°C on zero and within ±0.005%/°C on output, compensated from 14 to 158 °F (−10 to 70 °C).
  • Built for continuous loading. The design suits fatigue tests with continuous load, with a 150% safe overload.

Which LUK-A model do I need?

ModelRated capacityNatural frequency (approx.)Safe lateral force componentSafe momentWeight (approx., excl. cable)
LUK-A-5KN±1,124 lbf (±5 kN)7.4 kHz56.2 lbf (250 N)11.1 lbf·ft (15 N·m)1.98 lb (900 g)
LUK-A-10KN±2,248 lbf (±10 kN)10.8 kHz112 lbf (500 N)22.1 lbf·ft (30 N·m)1.98 lb (900 g)
LUK-A-20KN±4,496 lbf (±20 kN)8.5 kHz225 lbf (1 kN)44.3 lbf·ft (60 N·m)4.41 lb (2 kg)
LUK-A-50KN±11,240 lbf (±50 kN)11 kHz562 lbf (2.5 kN)111 lbf·ft (150 N·m)8.82 lb (4 kg)
LUK-A-100KN±22,481 lbf (±100 kN)9 kHz1,124 lbf (5 kN)369 lbf·ft (500 N·m)15.4 lb (7 kg)
LUK-A-200KN±44,962 lbf (±200 kN)7.5 kHz2,248 lbf (10 kN)738 lbf·ft (1 kN·m)39.7 lb (18 kg)
LUK-A-500KN±112,404 lbf (±500 kN)5.2 kHz5,620 lbf (25 kN)1,844 lbf·ft (2.5 kN·m)110 lb (50 kg)
LUK-A-1MN±224,809 lbf (±1 MN)5 kHz11,240 lbf (50 kN)3,688 lbf·ft (5 kN·m)198 lb (90 kg)
LUK-A-2MN±449,618 lbf (±2 MN)3.9 kHz22,481 lbf (100 kN)7,376 lbf·ft (10 kN·m)540 lb (245 kg)

Custom-made models with rated capacity over 2 MN are available, and TEDS-installed models are available. Contact us for either.

How is the LUK-A installed?

The load cell mounts by its outer flange with the load applied through the threaded center hole. The installation example shows the load cell bolted to a base, with the load introduced through a shaft or a piston and link.

  • When measuring hanging loads, prevent the shaft from turning.
  • The LUK-A is not applicable to setscrews.
  • Do not use special accessories such as ball-joint, hanger, and rotating attachments.
  • Eyebolt holes for handling: 2 × M16×20 on the 200 and 500 kN models, 6 × M16×20 on the 1 MN model, 6 × M20×20 on the 2 MN model.

When is the LUK-A the wrong choice?

  • Side loads and moments. Lateral force and moment limits are low relative to rated capacity, for example 250 N and 15 N·m on the 5 kN model.
  • Hanging loads with rotating fixtures. Ball-joints, hangers, and rotating attachments must not be used, and the shaft must be prevented from turning.
  • Temperatures outside −31 to 176 °F (−35 to 80 °C). That is the safe temperature range.

LUK-A FAQ

±5 kN to ±2 MN (±1,124 to ±449,618 lbf), in nine models.

Yes. Rated output is +2 mV/V ±1% in tension and approx. −2.0 mV/V in compression, with a sensitivity difference between loading directions of 0.4% RO or less.

Nonlinearity and hysteresis within ±0.1% RO, and repeatability 0.05% RO or less. On 500 kN and larger, these are within ±0.2% RO and 0.1% RO or less.

Yes, TEDS-installed models are available.

Custom-made models with rated capacity over 2 MN are available.

IP64 per JIS C 0920/IEC 60529.