  System Model DS-1000-4H DS-1000-6H DS-1000-8H DS-1000-10M
System
Specifications
Table Size (in) □ 15.7 □ 23.6 □ 31.5 □ 39.3
Rated
Force
Sine (lbf) 2,200 2,200 2,200 2,200
Random (lbf) 1,100 1,100 1,100 1,100
Shock (lbf) 3,300 3,300 3,300 3,300
Maximum Acceleration (g) 11.0 7.6 5.5 3.3
Maximum Velocity (in/s) 39.4 39.4 39.4 39.4
Maximum Displacement (inp-p) 2.0 2.0 2.0 2.0
Armature Mass (lbs) 200 290 400 660
Maximum
Frequency
Horizontal (Hz) 1,000 800 700 350
Vertical (Hz) 1,000 1,000 700 500
Maximum Load (lbs) 220 220 440 440
Power Requirements (kVA) 30 30 30 30
Primary Cooling Water (gal/min)
  System Model DS-2000-5H DS-2000-8M DS-2000-10M DS-2000-15M
System
Specifications
Table Size (in) □ 19.6 □ 31.5 □ 39.3 □ 59
Rated
Force
Sine (lbf) 4,400 4,400 4,400 4,400
Random (lbf) 2,200 2,200 2,200 2,200
Shock (lbf) 6,600 6,600 6,600 6,600
Maximum Acceleration (g) 15.3 8.3 6.8 2.9
Maximum Velocity (in/s) 39.4 39.4 39.4 35.4
Maximum Displacement (inp-p) 2.0 2.0 2.0 2.0
Armature Mass (lbs) 290 530 640 1,500
Maximum
Frequency
Horizontal (Hz) 800 500 350 250
Vertical (Hz) 800 800 500 350
Maximum Load (lbs) 440 660 1,100 1,100
Power Requirements (kVA) 66 66 66 66
Primary Cooling Water (gal/min)
  System Model DS-3000-5H DS-3000-8M DS-3000-10M DS-3000-15M
System
Specifications
Table Size (in) □ 19.6 □ 31.5 □ 39.3 □ 59
Rated
Force
Sine (lbf) 6,600 6,600 6,600 6,600
Random (lbf) 3,300 3,300 3,300 3,300
Shock (lbf) 9,900 9,900 9,900 9,900
Maximum Acceleration (g) 20.0 14.2 9.3 4.8
Maximum Velocity (in/s) 39.4 39.4 39.4 35.4
Maximum Displacement (inp-p) 2.0 2.0 2.0 2.0
Armature Mass (lbs) 330 460 700 1,370
Maximum
Frequency
Horizontal (Hz) 800 500 350 250
Vertical (Hz) 800 800 500 350
Maximum Load (lbs) 220 660 1,100 1,100
Power Requirements (kVA) 76 76 76 76
Primary Cooling Water (gal/min)
  System Model DS-5000-6H DS-5000-8H DS-5000-10M DS-5000-15M
System
Specifications
Table Size (in) □ 23.6 □ 31.5 □ 39.3 □ 59
Rated
Force
Sine (lbf) 11,000 11,000 11,000 11,000
Random (lbf) 6,600 6,600 5,500 5,500
Shock (lbf) 16,500 16,500 13,200 13,200
Maximum Acceleration (g) 35.7 20.8 16.6 6.0
Maximum Velocity (in/s) 39.4 39.4 35.4 35.4
Maximum Displacement (inp-p) 2.0 2.0 2.0 2.0
Armature Mass (lbs) 310 530 660 1,810
Maximum
Frequency
Horizontal (Hz) 800 700 350 250
Vertical (Hz) 1,000 800 500 350
Maximum Load (lbs) 660 660 1,100 1,540
Power Requirements (kVA) 104 104 106 106
Primary Cooling Water (gal/min) 98 98 95 95
  System Model DS-6000-6H DS-6000-8H DS-6000-10M DS-6000-15M
System
Specifications
Table Size (in) □ 23.6 □ 31.5 □ 39.3 □ 59
Rated
Force
Sine (lbf) 13,870 13,870 13,870 13,870
Random (lbf) 8,300 8,300 6,900 6,900
Shock (lbf) 20,800 20,800 16,600 16,600
Maximum Acceleration (g) 39.3 27.3 10.4 7.6
Maximum Velocity (in/s) 39.4 39.4 35.4 35.4
Maximum Displacement (inp-p) 2.0 2.0 2.0 2.0
Armature Mass (lbs) 350 510 1,320 1,810
Maximum
Frequency
Horizontal (Hz) 800 700 350 250
Vertical (Hz) 1,000 800 500 350
Maximum Load (lbs) 660 660 1,100 1,540
Power Requirements (kVA) 126 126 128 128
Primary Cooling Water (gal/min) 116 116 110 110
  • *Depending on the reference PSD or other operating conditions such as the specimen, one part of the controlled response may deviate from the reference PSD.
  • *The above is just an example. Specifications may be changed depending on test conditions. Please contact us for more information.