A wide range of models. The A-series meets the needs for such a versatile test environment. Advanced automatic energy saving, high level of functionality and a protected test environment. Ask us about our Innovative time & cost saving features found only on IMV technologies
IMV-SmartTM technology
① Improvement of performance
■ Improvement in excitation force
When compared with the conventional i- & J-series, the A-series has increased relative excitation force.
・Increased force per system power requirement ・Increased force per system mass ・Increased force per system size
■ Standard 3.0 inp-p displacement *Only for A30, A45, A65, A74
A-series has a displacement of 3.0 inp-p (3-inch stroke), which provides a good balance within the specifications for velocity, acceleration and displacement. This single system can be used for a very wide variety of tests.
■ Increase in frequency range
In addition to the increased displacement of 3.0 inp-p, the maximum frequency range is also increased when compared to the i- and J-series.
■ Adoption of new module
Featuring a power amplifier with an upgraded power element, the A-series achieves low noise and high efficiency. This upgrade is standard for all A-series models.
② User-friendly and secure
■ Lower power consumption
In comparison with the same class of conventional systems (i, J-series), the A-series achieves lower power consumption. Energy savings are increased across all force ranges thanks to an automatic energy-saving function.
■ International safety standards
A-series complies with international safety standards.
③ User-friendly interface
LAUNCHER
Rapid generation of tests from a set of pre-defined templates that conform to most international test standards.
SYSTEM MONITOR
Remote monitoring of test status over the internet.
The status of the test, as well as the amplifier or shaker operation, can be viewed on a remote PC using a standard internet browser.
Home screen
Home screen (Error)
Eco screen
Camera screen
Chamber screen
System Model
Unit
A11/EM1HAM
A22/EM2HAM
A30/EM3HAM
A45/EM4HAM
A65/EM5HAM
A74/EM10HAM
System Specifications
Frequency Range
Hz
0-4500
0-3300
0-2600
Rated Force
Sine
lbf
2,470
4,940
6,800
10,120
14,620
16,700
Random
lbf rms
Shock
4,945
9,890
13,500
20,240
29,240
50,000
High Velocity Shock
3,710
8,090
11,250
18,000
27,000
38,200
Maximum Acc.
g
102
92
g rms
65
g peak
204
185
183
184
153
166
154
163
169
Maximum Vel.
in/s
79
in/s peak
99
138
Maximum Disp.
inp-p
2.0
3.0
2.5
Maximum Travel
3.2
Maximum Load
lbs
441
661
882
1,323
2,205
Power Requirements
kVA
20.4
30
36
57
83
100
Breaker Capacity
A
50
60
125
175
Vibration Generator
Model
A11
A22
A30
A45
A65
A74
Armature Mass
24
49
73
110
159
164
Armature Diameter
φin
8.3
11
11.4
17.2
17.6
Allowable Eccentric Moment
lbf in
2,600
6,200
7,500
13,700
Dimensions
Width
in
37
41
44
52
Height
33
38
42
48
Depth
27
31
Shaker Body Diameter
23
29
Mass
2,381
3,527
4,409
6,614
9,260
10,585
Power Amplifier
EM1HAM-A11
EM2HAM-A22
EM3HAM-A30
EM4HAM-A45
EM5HAM-A65
EM10HAM-A74
Maximum Output
12
68
Amplifier Bay
s
1
2
3
46
69
77
34
1,036
1,235
1,300
2,535
Controller
Vibration Controller
See Vibration Controller K2
Cooling
Cooling Method
Air cooling
Blower
28
45
58
56
61
84
94
111
32
309
463
618
503
705
Wattage
kw
3.7
5.5
18.5
Duct Hose Diameter
φ
4.92
7.87
9.84
* Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
* Power supply: 3-phase 220/480V, 60Hz. A transformer is required for other supply voltages.
* Breaker capacity for 480V.
* Above 4,000Hz, the force rolls-of f at a rate of -6dB/oct.
* Above 2,000Hz, the force rolls-of f at a rate of -12dB/oct.
* An export license is required for exporting a shaker system of over 11,240 lbf sine force.
* For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock.
* Frequency range values vary according to sensor and vibration controller.
* Armature mass and acceleration may change when a chamber is added.
* Mass and dimensions may change for CE-marked systems.