Microprocessor-controlled programmable high efficiency DC power supplies | 1.5 kW | 3.0 kW
PS 9000 1U
Key Features
Flexible Autoranging Output: Offers a wide range of voltage and current combinations, reducing the need for multiple devices.
High Efficiency: Achieves up to 95% efficiency, minimizing energy loss and heat generation.
Compact Design: Slim 1U rack height ensures efficient use of space in laboratory or industrial settings.
Advanced Protection: Includes overvoltage, overcurrent, overpower, and overtemperature protection for enhanced safety and reliability.
Comprehensive Interfaces: Features built-in USB and Ethernet for digital control, with support for SCPI and ModBus RTU protocols.
Why Partner with W5 Engineering?
Expertise
At W5 Engineering, we specialize in power electronics, providing unmatched knowledge of EA Powered products. Our team of technical sales engineers ensures you find the perfect solution for even the most complex requirements.
Custom Solutions
We deliver customized configurations and integrations tailored to your unique applications. Whether for R&D, production, or testing, W5 Engineering ensures your power systems meet exact specifications.
Rapid Shipping
With on-hand inventory and advanced logistics, we minimize lead times to keep your projects on track. Enjoy seamless delivery and peace of mind with our reliable shipping network.
Customer Support
Available Models
Name | Power (W) | Current (A) | Voltage (V) | Ripple in CV (rms) | Ripple in CV (pp) |
---|---|---|---|---|---|
PS 9500-20 1U | 3000 W | 20 A | 500 V | 40 mV (BW 300 kHz) | 234 mV (BW 20 MHz) |
PS 9750-06 1U | 1500 W | 6 A | 750 V | 40 mV (BW 300 kHz) | 260 mV (BW 20 MHz) |
PS 9750-12 1U | 3000 W | 12 A | 750 V | 40 mV (BW 300 kHz) | 260 mV (BW 20 MHz) |
PS 9360-30 1U | 3000 W | 30 A | 360 V | 26 mV (BW 300 kHz) | 156 mV (BW 20 MHz) |
PS 9500-10 1U | 1500 W | 10 A | 500 V | 63 mV (BW 300 kHz) | 293 mV (BW 20 MHz) |
PS 9200-50 1U | 3000 W | 50 A | 200 V | 40 mV (BW 300 kHz) | 234 mV (BW 20 MHz) |
PS 9360-15 1U | 1500 W | 15 A | 360 V | 33 mV (BW 300 kHz) | 195 mV (BW 20 MHz) |
PS 9080-50 1U | 1500 W | 5 A | 80 V | 52 mV (BW 300 kHz) | 100 mV (BW 20 MHz) |
PS 9200-25 1U | 1500 W | 25 A | 200 V | 51 mV (BW 300 kHz) | 293 mV (BW 20 MHz) |
PS 9080-100 1U | 3000 W | 100 A | 80 V | 42 mV (BW 300 kHz) | 100 mV (BW 20 MHz) |
Product Information
Compact and Versatile DC Power Solutions for High-Performance Applications
Specifications
AC Supply
-
- 1500 W models: 100…264 V, 1ph+N or 2ph, 45…65 Hz, PF = 0.99
- 3000 W models: 180…264 V, 1ph+N or 2ph, 45…65 Hz, PF = 0.99
Derating
-
- 1500 W models: < 150 V AC to Pout max 1000 W
- 3000 W models: < 207 V AC to Pout max 2500 W
DC: Voltage
-
- Accuracy <0.1% of rated value
- Load regulation 0-100% <0.05% of rated value
- Line regulation ±10% ΔUAC <0.02% of rated value
- Regulation 10-100% load <2.2 ms
- Rise time 10-90% (CV) Max. 15 ms
DC: Current
-
- Accuracy <0.2% of rated value
- Load regulation 1-100% ΔUDC <0.15% of rated value
- Line regulation ±10% ΔUAC <0.05% of rated value
DC: Power
-
- Accuracy <1% of rated value
Overvoltage category: 2
Protection: OTP, OVP, OCP, OPP, PF
Insulation
-
- AC input to enclosure: 2500 V DC
- AC input to DC output: 2500 V DC
- DC output to enclosure (PE): Negative: max. 400 V
- DC positive: max. 400 V DC + output voltage
Degree of pollution: 2
Protection class: 1
Parallel Operation
-
- Possible, via Share Bus operation or via analog interface
- Master-Slave: No
Standards
-
- EN 60950
- EN 61326
- EN 55022 Class B
Environmental Conditions
-
- Operation temperature: 0…50 °C
- Storage temperature: -20…70 °C
- Humidity: <80%, non-condensing
- Operation altitude: <2000 m (1.242 mi)
Mechanical Construction
-
- Cooling: Temperature-controlled fans
- 1500 W
- Weight (2: ≈10.5 kg (23.1 lb)
- Dimensions (W x H x D) (3: 19“ x 1U x 500 mm (19.7”)
- 3000 W
- Weight (2: 11 kg (24.2 lb)
- Dimensions (W x H x D) (3: 19“ x 1U x 500 mm (19.7”)
Interfaces and Software
Built-In Interfaces
-
- USB
- Ethernet